How to Build an Ikea Lack Server Rack

Last updated October 31, 2026

Yes, it works: the legs of the LACK side table sit about 19 inches apart, so 19-inch gear screws straight between them, and one table gives roughly 8U of usable space. The catch is the legs, which are hollow below the top couple of inches, and a tabletop rated for a light load, so this is a light-equipment solution, not a stand-in for a four-post rack once a real server or a rack UPS shows up.

Why a LACK table works as a 19-inch rack

The table is 21 5/8 inches square on the outside, and each leg is about 2 inches wide, which leaves roughly 19 inches clear between them. That is a metric and imperial accident, not a design decision: the table was never meant to hold rack gear.

It happens to meet the standard anyway. A 19-inch panel is 19 inches wide, the holes sit 17.75 inches apart, and one rack unit is 1.75 inches tall, as the EIA/ECA-310-E standard sets out.

The load path is where the build gets weak. In a steel rack the weight goes into steel posts and then into the floor. In a LACK build the weight hangs from wood screws driven into particleboard legs, working in shear, and the joint between leg and top is a single dowel stud. That is the weakness the rest of this guide works around.

The tabletop is a paper honeycomb core between particleboard skins. It is strong across the span and weak for point loads and for screws, which matters the moment you think about bolting a caster or a bracket to it.

Which LACK table to buy

The 21 5/8 inch side table is the one to get. It measures 21 5/8 inches long, 21 5/8 inches wide and 17 3/4 inches high, holds about 8U, and its tabletop is rated for 22 lb. It comes in black-brown, white and white-stained oak effect.

The coffee table measures 35 3/8 inches long, 21 5/8 inches wide and 17 3/4 inches high. It is deeper, it has a lower shelf, and its 8U split into 4U on either side of that shelf. Its tabletop is rated for 44 lb. It suits a build that needs depth and a shelf, and it is less stable than two side tables stacked.

The 13 3/4 inch side table is too small for 19-inch gear. Do not buy it for this.

On the 21 5/8 versus 22 inch confusion: buy the 21 5/8 inch (55 cm) table. The 22 inch figure is a rounding artifact.

Build level 1, the no-drill shelf build

Assemble the table following its own instructions, then set gear on the tabletop, and on a lower table if you stack two. Nothing gets drilled, nothing gets voided, and the whole thing comes apart again in minutes.

This is the zero-risk option and the one most people should start with. Its limits are real: nothing is restrained, gear can slide, and there is no front-to-back support at all.

Build level 2, screw into the legs

Assemble the table, then mount gear between the left and right legs, working with the table on its side or upside down. Mount the first item tight against the tabletop, and screw every hole that fits, because each screw adds stability.

Use wood screws no longer than 1 inch, so they bite the leg without punching through the skin. Add screws near the leg-to-top joint to stop the legs buckling there under load. For deep units, a Z-bracket or an angle bracket at the rear ties the back of the chassis to the legs.

One alternative layout mounts gear to the rear face of the front legs, so the tabletop overhangs and shields the cabling.

Build level 3, rails and brackets

A pair of 16U rack rails fits a two-table stack. Clamp the rails to paired legs, drill the rail holes through the clamped pair, and fix with 14 by 1 inch wood screws.

Number and mark every leg and every hole before you take the stack apart, so it goes back together square. Rotating the tables relative to each other helps cut the wobble.

3D-printed corner brackets let you mount rails without drilling the legs at all, and that has become a mainstream option rather than a curiosity. Rails matter when gear uses square holes or when you want to slide a unit out. A single switch does not need them.

The hollow-leg problem and its four fixes

A LACK leg is a particleboard and fiberboard skin about 0.1 in (2.5 mm) thick, a wood-composite plug in roughly the top 2 inches (5 cm), another plug at the bottom, and air in the middle. Drill past the top plug and there is nothing left for a screw to bite, which is how wood screws tear out under a heavy item.

  • Keep every fixing inside the top 2 inches, where the plug is.
  • Use cavity fixings or molly-type anchors for anything mounted lower down.
  • Rip a 2x4 down to 1 3/4 inches square and slide it into the hollow leg, cut to the full leg length or to the mid-block if the leg has one. This is the community's standard fix.
  • Use 3D-printed brackets that clamp the leg instead of drilling it.

The tabletop is hollow too, except at the corners and over the honeycomb, so caster and bracket screws only hit solid material at the corners.

Weight, honestly

The tabletop's rated load is 22 lb on the side table and 44 lb on the coffee table. Real builds run far past those numbers, but the load path is the legs and the screws, not the top, so the rated figure is not the number to design to.

Where these builds fail is side impacts, horizontal shearing, repeated moves, and the plastic foot pads going brittle with age.

Put a UPS on the bottom tabletop, resting directly on it, never hanging from rails. And treat three tables as about the practical maximum anyone should trust with real equipment.

What nobody tells you

Noise is the biggest regret. 1U servers use small high-RPM fans and are loud, 2U is more manageable, and 4U can take large slow fans. A wooden open rack contains no sound at all, so if it lives in a living space, plan for larger, slower gear or put the server somewhere else.

Grounding is the second. A metal rack bonds to earth easily and wood does not, which matters for shielded cabling and for chassis-leakage paths.

Moisture is the third. Exposed particleboard swells and disintegrates once water gets past the foil wrap, so keep the build out of damp garages and basements.

Airflow needs a thought too. Rack gear moves air front to rear, and gear mounted flush to the front legs under a tabletop can recirculate hot air, so leave a U gap.

And it does not survive being dragged. Take the gear out before you move it.

Casters and mobility

Casters work, but only one of the four screws per caster lands in solid material, at the corner, and the rest go into hollow board. Choose casters rated for the loaded weight, and check whether they lock, because some common furniture casters do not.

Cutting the upper-tier legs shorter gives a lower stack. Tape the cut line first to stop the board splintering.

When to skip the build

A switch, a patch panel or light 1U to 2U gear is a good fit for a LACK build. One or two shallow servers are workable with rails and the hollow-leg fix, but treat that as a solution for one or two servers, not as a substitute for a four-post rack in a setup that will keep growing.

A full-depth server, sliding rails or a rack UPS means skip it. A four-post frame with adjustable depth is the right call there, because the chassis is supported at both ends and the rail kit's required front-to-rear distance, commonly 24 to 36 inches, sets the depth.

Anything that will grow points the same way. A rack that cannot take deeper servers or heavier batteries means building twice. And the build's cost advantage has narrowed as the table's price has risen and rails, casters and braces are added.

Alternatives to consider

A solid-pine shelf unit with a high per-shelf load rating and a cross-brace, anchored to the wall, carries more per level than a LACK table and looks like furniture.

A 10-inch mini-rack suits small gear that does not need 19-inch width. A 12U two-post or four-post open-frame steel rack is the direct like-for-like swap, with a warranty and a stated load rating.

A used full-size cabinet from classifieds or university surplus buys real depth and doors for less than new. A 3D-printed rack frame is the last option, and it suits small gear and a printer already on the bench.

It works, it is quick, and it is a light-equipment solution: switches, patch panels and light 1U to 2U gear sit happily in a LACK build, and the hollow-leg fix is what makes it last.

The one rule is that the moment a full-depth server or a rack UPS enters the picture, move to a four-post frame with adjustable depth.

Build order: buy the 21 5/8 inch side table, decide which of the three build levels you need, and fix the hollow legs before you load it.

Frequently asked questions

Most of the trouble in a LACK build comes from the legs, not the tabletop, so the screws, the load and the gear that does not belong in one decide whether it holds.

What size is the LACK table, and is it really 19 inches?

Each leg takes up about 2 inches, which leaves roughly 19 inches of clear space between them, and that is the gap the gear mounts into.

Which LACK should I buy, side table or coffee table?

The side table gives you about 8U in the smallest footprint. The coffee table trades stability for depth and a lower shelf, and its 8U splits into 4U above the shelf and 4U below it.

Is it 21 5/8 or 22 inches?

The 22 inch number is a rounding of the metric size and does not describe the table you want.

How much weight can a LackRack hold?

The side-table top is rated for 22 lb and the coffee table for 44 lb. Those are the top's figures, and the legs and screws are the real limit, so do not design to them.

How many U fit in one table?

About 8U, or almost 9U if you use every inch between the legs. Two tables plus a pair of 16U rails get you to roughly 12U of usable space.

What screws do I need?

Rails take 14 by 1 inch wood screws.

Can I put a rackmount UPS on the rails of a LACK build?

No. A UPS rests directly on the bottom tabletop, never hanging from rails, because the weight has to sit on the top rather than pull on screws driven into particleboard legs. The side table's top is rated for 22 lb and the coffee table's for 44 lb, and a rack UPS is one of the cases where a four-post frame is the right call instead.

How do I mount gear in the hollow legs?

Keep fixings within the first 2 inches (5 cm) of each leg, switch to cavity anchors below that, insert a 1 3/4 inch square dowel cut to the leg's full length, or clamp on 3D-printed brackets with no drilling at all.

How many LACK tables can I stack before it stops being sensible?

Three tables is the ceiling worth trusting with real equipment, and that is a judgement about the legs and screws rather than the tabletop rating. A single side table already gives you about 8U, so a stack multiplies the space but not the strength of any one joint. Past that point the build is asking particleboard legs and dowel studs to carry more than they were ever meant to.

Is it safe, will it collapse?

A static vertical load is fine. The risks are side impacts, repeated moves and moisture swelling the board, so keep it out of damp rooms and empty it before moving it.

Can I put it on wheels?

Yes, but only one screw per caster reaches solid material at the corner. Check the caster's load rating against the loaded weight, and check whether it locks.

Is a LackRack cheaper than a real rack?

Once you add rails, casters and braces, the total often climbs past the price of a basic steel frame. The build wins on speed and on fitting a small space, not always on cost.

Does it need grounding?

Wood is an insulator, so you have to run a bonding conductor from each chassis to a common earth point yourself. If you run shielded cabling or want a clean chassis-leakage path, plan that conductor before you load the table.

What are the alternatives?

A solid-pine shelf unit anchored to the wall, a 10-inch mini-rack, a 12U steel open frame, a used full-size cabinet, or a 3D-printed frame.

Can I paint it, and what colors does it come in?

The foil-wrapped surfaces take paint if you key them first with light sanding, then apply a primer made for slick laminates before the topcoat.

Will a patch panel and PDU fit alongside gear?

Yes, but depth and rear access are tight. A patch panel takes 1U and a PDU takes 1U, so both together use 2U of the roughly 8U available, and a deep PDU leaves little room behind the gear for cable bends.